D6600 | System Guide | 3.0 Operation
6 Bosch Security Systems, Inc. | 4/10 | 4998122712-04
For the appropriate configuration information for each
device, refer to the following installation guides:
C900TTL-E Dialer Capture Module Installation
Guide (P/N: 4998122718)
Conettix C900V2 Dialer Capture Ethernet
Module Installation Guide (P/N: F01U003472)
D9133TTL-E Serial Interface Module Installation
Guide (P/N: 4998122717)
Conettix DX4020 Ethernet Network Interface
Module Installation Guide (P/N: F01U045288)
Conettix D6680 Ethernet Network Adapter
Installation Guide (P/N: 4998138732)
Conettix D6682 Network Ethernet Adapter
Installation Guide (P/N: F01U078049)
Conettix ITS-DX4020-G GPRS/GSM IP
Communicator Module Installation and Operation
Guide (P/N: F01U163066)
2.1 Conettix D6600/D6100i
Pre-Installation Requirements
Consider the following pre-installation requirements
before attempting to install a Conettix D6600/D6100i
Network system. If you have any questions regarding
these items, contact the network administrator for the
network with which you will interface, or a Bosch
network engineer.
For UL Listed Fire Installations, shared
on-premises communications equipment
is required to be UL Listed for Information
Technology Equipment.
2.1.1 Setting Up the Conettix D6600/D6100i over
an Ethernet Network
The Ethernet network must use Ethernet cables.
The D6200 host computer must have a properly
configured Ethernet network interface card (NIC)
installed.
The D6600 must be connected to the Ethernet
network using a Bosch D6680/D6682 Network
Adapter or a D6100i must be connected to the
Ethernet network.
All alarm control panels, except Bosch control
panels, used in the Conettix system must use a
Bosch C900V2 or C900TTL-E.
Bosch control panels used in the Conettix system
should use a Bosch DX4020 Network Interface
Module or a D9133TTL-E Network Interface
Module.
2.1.2 Host Computer for Conettix D6600/D6100i
System Setup
The host computer uses the ARP and TELNET
DOS commands to configure the D6680/D6682,
D6100i, D9133TTL-E or DX4020, or
C900V2/C900TTL-E. The D6200 software can be
used instead of the ARP and TELNET
commands. Refer to the D6200 Software
Operation and Installation Guide
(P/N: 4998154991) and the appropriate network
device installation guide.
The host computer must have a properly
configured Ethernet network interface card (NIC)
installed.
The host computer must have the appropriate
Ethernet cable. Manually set the host computer's
IP address to an address that is acceptable to the
particular class of the network (refer to
Section
3.1 Setting Up the Host Computer,
page
6).
3.0 Operation
3.1 Setting Up the Host Computer
If the computer you plan to use for
programming the D6600, the D6100i, the
D6680/D6682, and the alarm panel
network adapters is already a functioning
workstation within the network you are
planning to utilize, proceed to Section 3.2
Network Failover Solution
(D6600 Only) on page 9.
The host computer is any computer or workstation
that is connected to the network you will use to
manage/administer the D6600/D6100i and other
devices. Any existing laptop or desktop computer on
the network can be used. However, for security
reasons, it is best that the computer not be used as a
regular workstation. This computer is also the
computer on which you install the D6200 Software.
The D6200 Software is used to program and
administer the D6600/D6100i and other devices.
Separate sections are provided for setting up the host
computer in Windows 2000, XP, Vista, and
Windows 7.