D6600 | System Guide | 4.0 Special Conettix D6600 Applications
14 Bosch Security Systems, Inc. | 4/10 | 4998122712-04
4.0 Special Conettix D6600 Applications
The following special application has been requested by Bosch dealers. It is included here to assist you if you
have the same requirement. If you have any questions, contact Technical Support at (800) 289-0096.
Emulating a Direct Serial Connection Over a LAN Using D6680/D6682 Ethernet Network Adapters
Some applications might require a direct serial connection be emulated over the network. One application that
would require this is where the D6600 is located on another part of the network from the Automation System.
To create a direct serial connection between the D6600 and the automation system, connect the COM3
automation output from the D6600 to the two D6680s/D6682s on the system. This is true serial cable emulation
over the network (refer to
Figure 6 on page 14).
Figure 6: Direct Serial LAN Connection Configuration
COM3
RS232
1 2 3
D6680
#1
D6680
#2
192.158.001.017 192.168.001.016
1 - D6600 Receiver
2 - Ethernet
3 - Automation System
The commands necessary for this configuration to automatically establish a connection are as follows. Note the
reference to the D6680s/D6682s by their number (Number 1 or Number 2). You must also ensure that the port
parameters such as speed, number of bits, flow control, and so on are correct on the D6680/D6682 for the
serial device that they are connected to.
D6680/D6682 No. 1:
*** basic parameters
Hardware: Ethernet TPI
IP address: 192.168.001.017, no gateway set
******* Channel 1 *******
Baudrate 9600, I/F Mode 4C, Flow 00
Port 7700
Remote IP Adr: 192.168.001.016, Port 7700
Connect Mode: C0
D6680/D6682 No. 2:
*** basic parameters
Hardware: Ethernet TPI
IP address: 192.168.001.016, no gateway set
******* Channel 1 *******
Baudrate 09600, I/F Mode 4C, Flow 00
Port 7700
Remote IP Adr: 192.168.001.017, Port 7700
Connect Mode: C0
For more information, refer to the D6680 Ethernet Network Adapter Installation Guide (P/N: 4998138732), or
the Conettix D6682 Network Ethernet Adapter Installation Guide (P/N: F01U078049).