Conettix D6600 Installation Guide Page 13

  • Download
  • Add to my manuals
  • Print
  • Page
    / 20
  • Table of contents
  • BOOKMARKS
  • Rated. / 5. Based on customer reviews
Page view 12
D6600 | System Guide | 3.0 Operation
.
Bosch Security Systems, Inc. | 4/10 | 4998122712-04 13
You can have two D6680s/D6682 on one D6600, one
with encryption On and the other with encryption Off.
This setup would allow for field devices to continue to
communicate with the D6680/D6682 with encryption
Off and begin the programming of the field devices to
send with encryption On to the second D6680/D6682.
This would allow devices to be programmed for
encryption without the loss of any signals or data to
the D6600. For more information on how to use two
D6680s/D6682s in a system as described, refer to
Section
If the device is a D9133TTL-E/DX4020,
change the destination IP address that is
currently programmed for the control panel to
the encryption-enabled D6680/D6682.
9. The devices that are programmed with encryption
communicate through the encryption-enabled
D6680 (v5.16 or later)/D6682, while the non-
encrypted devices, or those using encryption v5.1
or earlier, communicate through the original
D6680/D6682.
3.4.3 Using Two D6680s or D6682s in a
System
3.4.4 Obtaining the Latest D6200CD Software
on page 13.
If you do not already have the latest D6600CD (v1.10
or later) or D6200CD (v1.24 or later), you can obtain a
correct CD by of the following methods:
3.4.3 Using Two D6680s or D6682s in a System
If you will use two D6680s/D6682s in a system, both
using encryption (v5.16 or later) or one using
encryption and the other unencrypted, then do the
following steps:
Call and order a D6200CD from the Bosch
Customer Service group by calling 1-800-289-
0096.
1. The following equipment is needed:
Download the released software, firmware, and
documentation from the Bosch web site.
One additional D6680/D6682
One additional static IP Address
Downloading
1. Connect to the company web site:
A D6672 COM1 Expansion Kit for the D6600
www.boschsecurity.us
2. D6680/D6682 Number 1 is the network adapter
that is currently running.
, then search for D6600.
You can download software, firmware, and
documentation from the Conettix D6600 product
page.
3. Assuming the first D6680/D6682 is already set up
and running, connect the second D6600 on
COM1 to the D6600/D6100i as described in the
D6600/D6100i Network Operation and Installation
Guide (P/N: 4998122704).
4. Enable encryption in the second D6680/D6682 as
described in the Conettix D6680 Network Adapter
Installation Guide (P/N: 4998138732), or the
Conettix D6682 Network Ethernet Adapter
(P/N: F01U078049).
5. Add a receiver to the list of receivers under
Administration Æ Connection Settings with the
IP address and encryption key of the second
D6680/D6682.
6. Select the receiver name added in the previous
step.
7. Verify that the D6200 can communicate with the
D6600.
8. Program field devices to communicate with the
encryption enabled D6680/D6682:
Verify that the TTL-E NIM has the correct
firmware (v5.16 or later).
Enable encryption on the NIM device with the
same key that is entered in the D6680/D6682.
If the device is a C900TTL-E/C900V2,
change the destination IP address to match
the IP address in the encryption-enabled
D6680/D6682.
Download times can vary depending on
the speed of your Internet connection.
2. Read the D6600/D6100i Release Notes
(P/N: 4998122709) for the latest information
regarding software installation, changes, and
added features.
A decompression program that handles
.zip files is required in order to open the
zipped file.
3. Follow the installation procedures for software
and firmware in the Software Upgrade Procedure
section of the D6600/D6100i Operation and
Installation Guide (P/N: 4998122704).
Page view 12